Product features:
◆Wide input voltage range (4:1)
◆ Efficiency as high as 88%
◆ Isolation voltage 1500VDC
◆ Working temperature: -40℃~+70℃
◆ Input undervoltage, output overvoltage, short circuit protection, overcurrent protection
◆ Bare metal meets CISPR22/EN55022 CLASS A
◆ International standard pin method
◆ Three-year warranty period
Selection table | |||||||
Certification |
Product model | input voltage(VDC) | output | Efficiency②(%,Min./Typ.) @full load | Maximum capacitive load③ (μF) | ||
nominal value (range value) | maximum value | Output voltage (VDC) | Output current (mA) (Max./Min.) | ||||
Safdar6-24D05B |
24 (9-36) |
40 | ±5 | ±600/±30 | 81/83 | 680 | |
Safdar6-24D12B | ±12 | ±250±12 | 85/87 | 330 | |||
Safdar6-24D15B | ±15 | ±200±/10 | 86/88 | 220 | |||
Safdar6-24D24B | ±24 | ±125±6 | 85/87 | 100 | |||
Safdar6-24h03b | 3.3 | 1500/57 | 77/79 | 1800 | |||
Safdar6-24S05B | 5 | 1200/60 | 81/83 | 1000 | |||
Safdar6-24S09B | 9 | 667/33 | 82/84 | 1000 | |||
Safdar6-24S12B | 12 | 500/25 | 85/87 | 470 | |||
Safdar6-24S15B | 15 | 400/20 | 86/88 | 220 | |||
Safdar6-24S24B | 24 | 250/13 | 85/87 | 100 | |||
Safdar6-48D05B |
48 ( 18-75) |
80 | ±5 | ±600/±30 | 81/83 | 680 | |
Safdar6-48D12B | ±12 | ±250/±12 | 85/87 | 330 | |||
Safdar6-48D15B | ±15 | ±200/±10 | 86/88 | 220 | |||
Safdar6-48S03B | 3.3 | 1500/75 | 78/80 | 1800 | |||
Safdar6-48S05B | 5 | 1200/60 | 82/84 | 1000 | |||
Safdar6-48S12B | 12 | 500/25 | 85/87 | 470 | |||
Safdar6-48S15B | 15 | 400/20 | 86/88 | 220 | |||
Safdar6-48S24B | 24 | 250/13 | 85/87 | 100 | |||
Note: ① The input voltage cannot exceed this value, otherwise it may cause permanent and unrecoverable damage; ②The above efficiency values are measured when input nominal voltage and output rated load; ③The capacitive loads of the positive and negative outputs are the same. | |||||||
Professional Guide to DC-DC Industrial Power Modules: Core Elements to Ensure Stable Operation of Industrial Equipment
summary: DC-DC industrial power module is the core power supply component of industrial automation, control systems and field equipment. Its reliability directly affects the stable operation of the entire production system. This article analyzes in detail the technical requirements, selection points, common problems and systematic fault solutions of industrial-grade power modules.
1. Key characteristics of industrial-grade DC-DC power modules
The industrial environment has stricter requirements for power modules than commercial-grade products, which are mainly reflected in:
wide temperature range:Supports an operating temperature range of -40℃ to +85℃, adapting to harsh industrial environments
High anti-interference ability: Passed strict EMC testing and complied with IEC/EN 61000-4 series standards
Strengthen isolation protection: The isolation voltage between input and output is as high as 3000-4000VDC to ensure system safety
Resistant to vibration and shock: Complies with IEC 60068-2 standard, resistant to mechanical vibration and shock
Wide voltage input: Supports wide range input such as 9-36V and 18-75V, adapting to fluctuations in industrial power grids
2. Frequently Asked Questions about DC-DC Industrial Power Modules
Q1: What are the most important issues to pay attention to when using power modules in industrial environments?
A: Industrial applications require special attention:
voltage fluctuation: Industrial power grids have interferences such as surges and drops, which require a wide input range design.
temperature extremes: High-temperature workshops or outdoor equipment need to consider temperature derating
electromagnetic interference: Frequency converters, motors and other equipment produce strong EMI interference
mechanical stress: Vibrating environment may cause solder joints to crack and connectors to loosen.
Q2: How to choose the appropriate power module for the PLC system?
A: Key points for selecting power supply for PLC system:
Power calculation: Count the power consumption of all I/O modules and communication modules, leaving a 30% margin.
Voltage matching: Confirm the voltage requirements of peripheral equipment such as sensors and actuators
Quarantine requirements: Analog modules require high isolation power supply to prevent interference
Certification standards: Choose products certified by UL/CE to ensure safety and compliance
Q3: How should the derating design of industrial power modules be carried out?
A: Correct derating design:
Temperature derating: When the ambient temperature exceeds 50℃, the power decreases by 2-3% for every 1℃ increase.
Altitude derating: When the altitude exceeds 2000 meters, the power will be reduced by 1% for every 100 meters of elevation.
Lifespan considerations: At the maximum operating temperature, power usage does not exceed 80% of the rated value
Reliability requirements: It is RECOMmended to use 50% power derating for critical systems
Q4: How to deal with transient voltage interference in industrial environments?
A: Transient protection measures:
Input protection: Configure TVS tubes and varistor to absorb surge energy
Filter design: Use π-type filter to suppress conducted interference
Layout optimization: Shorten the input leads and reduce the loop area
Grounding treatment: Use single point grounding to avoid ground loop interference
3. DC-DC industrial power module troubleshooting guide
Possible causes of malfunctions, troubleshooting steps and solutions
No output1. Abnormal input power supply
2. Enable signal error
3. Module damaged
4. Wiring error 1. Measure the input voltage
2. Check the EN pin status
3. Test module static resistance
4. Confirm the correctness of wiring 1. Restore power supply
2. Correctly configure EN
3. Replace the module
4. Rewiring
Output is unstable1. Overloaded
2. Input voltage fluctuation
3. The temperature is too high
4. Insufficient compensation 1. Measure load current
2. Monitor input waveform
3. Check the temperature
4. Analyze dynamic response 1. Reduce load
2. Stable input
3. Improve heat dissipation
4. Optimize compensation
Overheating protection1. High ambient temperature
2. Poor heat dissipation
3. The load is too large
4. Fan failure 1. Monitor the ambient temperature
2. Check the radiator
3. Verify payload
4. Test the fan 1. Lower the temperature
2. Enhance heat dissipation
3. Reduce load
4. Replace the fan
EMC test failed1. Insufficient filtering
2. Poor grounding
3. Improper layout
4. Imperfect shielding 1. Analyze the spectrum
2. Check grounding
3. Evaluate the layout
4. Verify shielding 1. Enhance filtering
2. Improve grounding
3. Optimize layout
4. Strengthen shielding
4. Key points for selecting industrial power modules
environmental adaptability selection
Temperature level:Select the appropriate temperature level according to the installation location
Protection level: Choose IP5x for dusty environment and IP6x for humid environment.
Certification requirements: Hazardous environments require ATEX certification, railways require EN 50155
Electrical parameter considerations
input range: Select a model with a voltage fluctuation range that is 20% wider than the actual voltage.
Output accuracy: Analog circuit requires ±1%, digital circuit ±3% is sufficient.
Isolation voltage: The safety circuit needs to be isolated, and ordinary signal isolation can be basically insulated.
reliability index
MTBF: Select products with MTBF > 1 million hours for key systems
life expectancy: Consider the relationship between capacitor life and operating temperature
Warranty period: Industrial grade products should provide a 3-5 year warranty
5. Best practices for installation and maintenance
Installation specifications
Heat dissipation considerations: Leave enough space for heat dissipation, module spacing ≥10mm
Wiring requirements: Use shielded cables, and run power lines and signal lines separately.
Grounding treatment: Use star type grounding, and the grounding wire should be as short and thick as possible
Maintenance points
Regular inspection: Check the connection tightening status every six months
Cleaning and maintenance: Clean radiator dust regularly
Parameter monitoring: Record operating temperature, input and output voltage and other parameters
preventive maintenance
Thermal imaging detection: Regularly use thermal imaging cameras to detect temperature distribution
Parametric testing: Test output accuracy and ripple every quarter
Aging prediction: Predict capacitor life based on run time
in conclusion
The correct selection and application of DC-DC industrial power modules is the key to ensuring the stable operation of industrial equipment. By fully understanding the characteristics of the industrial environment, following design specifications, and implementing effective maintenance strategies, system reliability and service life can be significantly improved. It is recommended to work with a professional technical team to select the most appropriate power solution based on specific application scenarios.
Address: No. 25, Huoju South Street, Development Zone, Zhuozhou City, Hebei Province
Tel: 15600309099 (Mr. Lu)
Email: sales@chewins.net
Copyright © Beijing Huayang Changfeng Technology Co., Ltd.
This website uses cookies to ensure you get the best experience on our website.