Login | Register
Product Center
Home > Products > ——>3-10W > DC-DC industrial power module CFDR6

DC-DC industrial power module CFDR6

Datasheet download

Product features:

◆Wide input voltage range (4:1)

◆ Efficiency as high as 88%

◆ Isolation voltage 1500VDC

◆ Working temperature: -40℃~+70℃

◆ Input undervoltage, output overvoltage, short circuit protection, overcurrent protection

◆ Bare metal meets CISPR22/EN55022 CLASS A

◆ International standard pin method

◆ Three-year warranty period

Selection table

Certification

 

Product model

input voltage(VDC)

output

Efficiency②(%,Min./Typ.) @full load


Maximum capacitive load

(μF)

nominal value

(range value)



 maximum value


Output voltage


(VDC)

Output current (mA) (Max./Min.)



Safdar6-24D05B

 

 

 

 

 

24




(9-36)

 

 

 

 

 

40

±5

±600/±30

81/83

680

Safdar6-24D12B

±12

±250±12

85/87

330

Safdar6-24D15B

±15

±200±/10

86/88

220

Safdar6-24D24B

±24

±125±6

85/87

100

Safdar6-24h03b

3.3

1500/57

77/79

1800

Safdar6-24S05B

5

1200/60

81/83

1000

Safdar6-24S09B

9

667/33

82/84

1000

Safdar6-24S12B

12

500/25

85/87

470

Safdar6-24S15B

15

400/20

86/88

220

Safdar6-24S24B

24

250/13

85/87

100

Safdar6-48D05B

 

 

 

48

( 18-75)

 

 

 

 

80

±5

±600/±30

81/83

680

Safdar6-48D12B

±12

±250/±12

85/87

330

Safdar6-48D15B

±15

±200/±10

86/88

220

Safdar6-48S03B

3.3

1500/75

78/80

1800

Safdar6-48S05B

5

1200/60

82/84

1000

Safdar6-48S12B

12

500/25

85/87

470

Safdar6-48S15B

15

400/20

86/88

220

Safdar6-48S24B

24

250/13

85/87

100

 Note: ① The input voltage cannot exceed this value, otherwise it may cause permanent and unrecoverable damage;

②The above efficiency values ​​are measured when input nominal voltage and output rated load;

③The capacitive loads of the positive and negative outputs are the same.


  Professional Guide to DC-DC Industrial Power Modules: Core Elements to Ensure Stable Operation of Industrial Equipment

  summary: DC-DC industrial power module is the core power supply component of industrial automation, control systems and field equipment. Its reliability directly affects the stable operation of the entire production system. This article analyzes in detail the technical requirements, selection points, common problems and systematic fault solutions of industrial-grade power modules.

  1. Key characteristics of industrial-grade DC-DC power modules

The industrial environment has stricter requirements for power modules than commercial-grade products, which are mainly reflected in:

  wide temperature range:Supports an operating temperature range of -40℃ to +85℃, adapting to harsh industrial environments

  High anti-interference ability: Passed strict EMC testing and complied with IEC/EN 61000-4 series standards

  Strengthen isolation protection: The isolation voltage between input and output is as high as 3000-4000VDC to ensure system safety

  Resistant to vibration and shock: Complies with IEC 60068-2 standard, resistant to mechanical vibration and shock

  Wide voltage input: Supports wide range input such as 9-36V and 18-75V, adapting to fluctuations in industrial power grids

  2. Frequently Asked Questions about DC-DC Industrial Power Modules

  Q1: What are the most important issues to pay attention to when using power modules in industrial environments?

A: Industrial applications require special attention:

  voltage fluctuation: Industrial power grids have interferences such as surges and drops, which require a wide input range design.

  temperature extremes: High-temperature workshops or outdoor equipment need to consider temperature derating

  electromagnetic interference: Frequency converters, motors and other equipment produce strong EMI interference

  mechanical stress: Vibrating environment may cause solder joints to crack and connectors to loosen.

  Q2: How to choose the appropriate power module for the PLC system?

A: Key points for selecting power supply for PLC system:

  Power calculation: Count the power consumption of all I/O modules and communication modules, leaving a 30% margin.

  Voltage matching: Confirm the voltage requirements of peripheral equipment such as sensors and actuators

  Quarantine requirements: Analog modules require high isolation power supply to prevent interference

  Certification standards: Choose products certified by UL/CE to ensure safety and compliance

  Q3: How should the derating design of industrial power modules be carried out?

A: Correct derating design:

  Temperature derating: When the ambient temperature exceeds 50℃, the power decreases by 2-3% for every 1℃ increase.

  Altitude derating: When the altitude exceeds 2000 meters, the power will be reduced by 1% for every 100 meters of elevation.

  Lifespan considerations: At the maximum operating temperature, power usage does not exceed 80% of the rated value

  Reliability requirements: It is RECOMmended to use 50% power derating for critical systems

  Q4: How to deal with transient voltage interference in industrial environments?

A: Transient protection measures:

  Input protection: Configure TVS tubes and varistor to absorb surge energy

  Filter design: Use π-type filter to suppress conducted interference

  Layout optimization: Shorten the input leads and reduce the loop area

  Grounding treatment: Use single point grounding to avoid ground loop interference

  3. DC-DC industrial power module troubleshooting guide

Possible causes of malfunctions, troubleshooting steps and solutions

  No output1. Abnormal input power supply

2. Enable signal error

3. Module damaged

4. Wiring error 1. Measure the input voltage

2. Check the EN pin status

3. Test module static resistance

4. Confirm the correctness of wiring 1. Restore power supply

2. Correctly configure EN

3. Replace the module

4. Rewiring

  Output is unstable1. Overloaded

2. Input voltage fluctuation

3. The temperature is too high

4. Insufficient compensation 1. Measure load current

2. Monitor input waveform

3. Check the temperature

4. Analyze dynamic response 1. Reduce load

2. Stable input

3. Improve heat dissipation

4. Optimize compensation

  Overheating protection1. High ambient temperature

2. Poor heat dissipation

3. The load is too large

4. Fan failure 1. Monitor the ambient temperature

2. Check the radiator

3. Verify payload

4. Test the fan 1. Lower the temperature

2. Enhance heat dissipation

3. Reduce load

4. Replace the fan

  EMC test failed1. Insufficient filtering

2. Poor grounding

3. Improper layout

4. Imperfect shielding 1. Analyze the spectrum

2. Check grounding

3. Evaluate the layout

4. Verify shielding 1. Enhance filtering

2. Improve grounding

3. Optimize layout

4. Strengthen shielding

  4. Key points for selecting industrial power modules

  environmental adaptability selection

  Temperature level:Select the appropriate temperature level according to the installation location

  Protection level: Choose IP5x for dusty environment and IP6x for humid environment.

  Certification requirements: Hazardous environments require ATEX certification, railways require EN 50155

  Electrical parameter considerations

  input range: Select a model with a voltage fluctuation range that is 20% wider than the actual voltage.

  Output accuracy: Analog circuit requires ±1%, digital circuit ±3% is sufficient.

  Isolation voltage: The safety circuit needs to be isolated, and ordinary signal isolation can be basically insulated.

  reliability index

  MTBF: Select products with MTBF > 1 million hours for key systems

  life expectancy: Consider the relationship between capacitor life and operating temperature

  Warranty period: Industrial grade products should provide a 3-5 year warranty

  5. Best practices for installation and maintenance

  Installation specifications

  Heat dissipation considerations: Leave enough space for heat dissipation, module spacing ≥10mm

  Wiring requirements: Use shielded cables, and run power lines and signal lines separately.

  Grounding treatment: Use star type grounding, and the grounding wire should be as short and thick as possible

  Maintenance points

  Regular inspection: Check the connection tightening status every six months

  Cleaning and maintenance: Clean radiator dust regularly

  Parameter monitoring: Record operating temperature, input and output voltage and other parameters

  preventive maintenance

  Thermal imaging detection: Regularly use thermal imaging cameras to detect temperature distribution

  Parametric testing: Test output accuracy and ripple every quarter

  Aging prediction: Predict capacitor life based on run time

  in conclusion

The correct selection and application of DC-DC industrial power modules is the key to ensuring the stable operation of industrial equipment. By fully understanding the characteristics of the industrial environment, following design specifications, and implementing effective maintenance strategies, system reliability and service life can be significantly improved. It is recommended to work with a professional technical team to select the most appropriate power solution based on specific application scenarios.


ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
Sitemap

Copyright © Beijing Huayang Changfeng Technology Co., Ltd.

This website uses cookies to ensure you get the best experience on our website.

Accept Reject